Cleanroom

Cleanroom

Request Information

Request Information

Cleanroom

*=required field

Low-Lint & Lint-Free Wipes for Cleanroom & Critical Cleaning

Techspray offers a large array of wipes for a variety of applications. Cleanroom wipes meet the particulate count and extractable standards for Class 10 / ISO Class 4 and Class 100 / ISO Class 5 cleanrooms.

Cleanroom Wipers: Meet the particulate count and extractable standards for Class 10 / ISO Class 4 and Class 100 / ISO Class 5 cleanrooms.

Maintenance Wipers: Lower cost, high-quality wipers for heavy-duty cleaning. Best for Class 1000 / ISO Class 6 cleanrooms or higher.

Foam swabs:  Ideal for more precision cleaning where linting needs to be avoided. The tight cell structure of the polyurethane foam is less likely to snag compared to cotton, and it is still highly absorbent. 

Techclean Absorbwipe Techclean Absorbwipe
Soft absorbent non-woven poly wiper for sensitive surfaces
Techclean Anti-Static Wipe Techclean Anti-Static Wipe
Class 10 anti-static knit polyester wipe
Techclean Purwipe Techclean Purwipe
100% polyester, strong & lint-free wipe
Techclean Wiper Techclean Wiper
Class 100 high-absorbency poly/cellulose wipe
Large Foam Swabs 	Super-Tip Foam Swab
5 to 6" long swabs with rigid foam heads
Small Foam Swabs Mini-Tip Foam Swab
Small foam swabs for high precision cleaning

FAQ's

What are the proper cleanroom wiping techniques?
Proper cleanroom wiping techniques are essential to maintain the cleanliness and integrity of the controlled environment. Cleanrooms are used in various industries, such as pharmaceuticals, electronics, aerospace, and biotechnology, where even the tiniest contaminants can be detrimental to the processes or products being produced. Here are some key steps and guidelines for cleanroom wiping:
  • Use the right materials: Select appropriate wiping materials that are compatible with the cleanroom environment. Common materials include non-woven wipes, microfiber wipes, and polyester wipes. They should have low particle generation, low linting, and be free from contaminants.
  • Wear proper cleanroom attire: Before starting any wiping procedure, ensure you are wearing the appropriate cleanroom garments, including gloves, a gown, and a face mask, to prevent the introduction of particles and skin oils.
  • Prepare the wiping solution: If a wiping solution is necessary, use a cleanroom-approved cleaning agent. Some cleanrooms use isopropyl alcohol or other specialized cleaning solutions. Ensure the solution is properly diluted according to the manufacturer's recommendations.
  • Follow a wiping pattern: Adopt a systematic wiping pattern to ensure complete coverage of the area. Start from the cleanest area and work towards the dirtier zones. Avoid cross-contamination between different surfaces.
  • Use gentle pressure: Apply only light pressure while wiping to avoid damaging sensitive surfaces or releasing particles into the air.
  • One-directional wiping: Whenever possible, use one-directional wiping, moving from one side to the other, to prevent particles from being redistributed.
  • Change wipes regularly: Replace wipes frequently to avoid spreading contaminants. Dispose of used wipes properly according to cleanroom protocols.
  • Avoid wiping overhead surfaces: Wiping overhead surfaces can release particles downward, contaminating lower surfaces. Use alternative cleaning methods for these areas.
  • Follow cleanroom class-specific protocols: Different cleanrooms have different cleanliness classifications (ISO Class 1 to 9, for example), each with its specific protocols. Ensure you follow the appropriate procedures for your cleanroom class.
  • Perform regular training: All cleanroom personnel should receive proper training on cleanroom wiping techniques to ensure consistency and effectiveness.
Always adhere to the cleanroom's specific Standard Operating Procedures (SOPs) and guidelines while performing any cleaning tasks. Proper cleaning and wiping techniques are critical to maintaining a controlled environment and ensuring the quality of products or processes within the cleanroom.

What type of wipe is best for cleanrooms?

Cleanroom wipes used for critical applications are almost always knitted synthetic fibers. Knitted polyester fabric, like used for Techclean Purwipe (part #2355-100), is the most popular wipe material for cleanrooms. Knitted polyester is made clean, contaminants can easily be removed from knitted polyester in a cleanroom laundry, and polyester is relatively inexpensive. Non-woven wipes do not offer the advantage of ease in cleaning as their composition causes them to disintegrate in a cleanroom washing machine or cleanroom drier.  Techclean Anti-Static Wipes (#2362-150) are also woven polyester, but include stripes of DuPont’s NEGA-STAT carbon yarn. This prevents static generation, which is especially important when dry wiping. Anti-Static Wipes are packaged in a class 10 cleanroom, so ideal for cleanroom applications. This wipe is widely used on smart phone and pad computer screens in assembly or repair operations. Wiping glass screens with standard polyester will tend to generate static and attract dust.