Apply to clean, moisture-free surface.  Areas not requiring coating should be masked. Application: Coating may be applied by spraying, brushing, dipping or flow coating.  Allow coating to flow around components. Cure:  Room temperature cure: A 1.0 mil coating will be tack-free in 9 minutes.  Full cure requires 15 hours @ 74˚F (23˚C). Heat cure: 55 minutes @ 131˚F (55˚C). An open vessel of water placed in the drying chamber will facilitate curing. UV detectable for QC inspection. Removal:  Coating may be removed by soaking in Conformal Coating Remover. Use TraceTech™ Conformal Coating Remover Pen for spot removal. After the new component is installed, areas should be cleaned and re-coated.